C Name
CPX_PARAM_PROBE
C++ Name
Probe
Java Name
Probe
.NET Name
Probe
InteractiveOptimizer
mip strategy probe
Identifier
2042
Description
Sets the amount of probing on variables to be performed before MIP branching. Higher settings perform more probing. Probing can be very powerful but very time-consuming at the start. Setting the parameter to values above the default of 0 (automatic) can result in dramatic reductions or dramatic increases in solution time, depending on the model.
Values
Value |
Meaning |
---|---|
-1 |
No probing |
0 |
Automatic: let CPLEX choose; default |
1 |
Moderate probing level |
2 |
Aggressive probing level |
3 |
Very aggressive probing level |